4. Metal work in lateral malleolus with the syndesmotic screw to be broken in a 30-year-old male.
Treatment: Removal all the implant work plus the syndesmotic screw with specific technique.
The lag screw did not remove I. Ten months down the line of the procedure, anteroposterior x-ray ankle shows the broken screw II. During the procedure a specific technique is using to remove the major part of the broken screw III. Anteroposterior view during the procedure is showing that the broken screw has been removed